Toray Method
Testing Procedure
(1) Take 3 sample testpieces from the fabric, each testpiece measuring 25cm by 25cm. Weigh each testpiece and note the weight (g).
(2) Pour 500cc of hot water (402) into a 500cc beaker.
(3) lace each testpiece over a beaker, outer surface face-up and secure it using two rubber bands to prevent water vapor from escaping.
(4) Place the beakers with the attached testpieces in a temperature/humidity controlled chamber*1 maintained at 10, 60%RH.
(5) Remove the beakers from the chamber after 1 hour and weigh each testpiece*2.
(6) Use filter paper to absorb the condensed water and weigh the testpiece.
(7) Calculate the levels of condensation and moisture absorption using these formulas:
 



where
W1: Pre-test weight of testpiece (g)
W2: Weight of testpiece after 1 hour
W3: Weight of testpiece after condensed water has been absorbed with filter paper
S: Beaker opening area ()
Notes
*1 Do not place more than five beakers in the chamber for each test in order to maintain correct testing conditions.
*2 Carefully remove rubber bands from each beaker making sure that no condensed water drips from the testpiece and condensed water does not spill.